Tel0512-83555991
ADICO environmental test chambers are widely used in aerospace, military units, electrical and electronics, instrumentation, materials and equipment, parts and accessories, etc. The adaptability test under the conditions of rapid changes in atmospheric temperature and the safety test of electronic components provide reliability tests, product screening, etc., and at the same time can pass this test to carry out product quality control.
Support hotline:0512-83555991
Product Usage:
ADICO environmental test chambers are widely used in aerospace, military units, electrical and electronics, instrumentation, materials and equipment, parts and accessories, etc.
The adaptability test under the conditions of rapid changes in atmospheric temperature and the safety test of electronic components provide reliability tests, product screening, etc., and can pass this test to carry out product quality control.
fulfill the standard:
GB/T2423.1-2008 (IEC60068-2-1:2007) Low temperature test method Ab
GB/T2423.2-2008 (IEC60068-2-2:2007) high temperature test method Bb
GJB150.3-1986 high temperature test
GJB150.3A-2009 high temperature test
GJB150.4-1986 low temperature test
GJB150.4A-2009 low temperature test
GJB150.9A-2009 Damp heat test
GB/T2423.3-2006 (IEC60068-2-78:2012) Constant damp heat test method Cab
GB/T2423.4-2008 (IEC60068-2-30:2005) Alternating damp heat test method Db
GB/T2423.34-2012 (IE60068-2-38-2009) temperature and humidity combination test
ISO 16750-4/GMW 3172-2012: HT/HHC/HHCO
VW80000/BMW GS95003-4
GJB150.9A-2009 Damp heat test
JJF1101-2019 Environmental test equipment temperature and humidity calibration specification
Technical conditions of GB/T10586-2006 damp heat test chamber
And new energy battery packs and other test standards
Inner dimension | 3000×3000×2000 mm (W*D*H)Subject to customer needs | ![]() |
External dimensions | 4050×3330×2070 mm (W*D*H) | |
temperature range | -70℃~+150 ℃ | |
Humidity range | 10 %~98% RH | |
Cooling rate | 20 ℃~-70 ℃/ ≦90 min(Under no load) | |
Heating rate | 20 ℃~+150 ℃/ ≦45 min | |
Temperature fluctuation | ≦±0.5℃ | |
Uniformity of temperature distribution | ≦2.0℃(Under no load) | |
Humidity fluctuation | ≦±3.0% | |
Humidity distribution uniformity | ≦ 3.0% (Under no load) | |
Temperature deviation | ≦±1.0℃ | |
Humidity deviation | ≦±3.0% (Under no load) |
The equipment has the advantages of reliability, stability and energy saving.
技术支持:腾云网