Constant temperature and humidity room

Back to list page

Custom non-standard high and low temperature rooms can be used for fixed-point temperature and humidity, program temperature and humidity, and linear high and low temperature changes.

Online consultation

Support hotline:0512-83555991

Product Details

ADICO constant temperature and humidity room meets:


GB/T2423.1 Test A: Low temperature test method


GB/T2423.2 Test B: High temperature test method


Technical conditions of GB/T11158 high temperature test chamber


Technical conditions of GB/T10589 low temperature test chamber


GB/T 2423.22 test Nb: temperature change test GB/T 2423.4 test Db: alternating damp heat test;


GB/T 31467.1 Lithium-ion power battery packs and systems for electric vehicles Part 1: Test procedures for high-power applications


GB/T 31467.2 Lithium-ion power battery packs and systems for electric vehicles Part 2: Test procedures for high-energy applications


GB/T 31467.3 Lithium-ion power battery packs and systems for electric vehicles Part 3: Safety requirements and test methods


GB/T 31484 Cycle life requirements and test methods for power batteries for electric vehicles


GB/T 31485 Safety requirements and test methods for power batteries for electric vehicles


GB/T 31486 Electric performance requirements and test methods for power batteries for electric vehicles


GB/T2423.3 Constant humidity test GJB150.3-2009 high temperature test GJB150.4-2009 low temperature test


GJB150.9 damp heat test test standard requirements GB/T5170.2-2008 temperature test equipment


GB/T5170.5 damp heat test equipment, meeting the requirements of 8.1 damp heat alternating cycle test in "Test Procedures for Lithium Ion Power Batteries for Electric Vehicles Part 2 High Energy Applications"


Technical parameter

1

Studio size

22m3

4600×1900×2600(Depth × width × height, unit mm)

2

load

No load

3

Operating temperature range

-45℃~85℃ (heating rate≥3℃/min, cooling rate≥2℃/min) no load

Temperature overshoot

2

Rising and cooling rate

Under the specified factory conditions:

Temperature range

Heating rate

Cooling rate

+85℃~-45

≥3℃/min, no load, average throughout the whole process

≥2℃/min, no load, average throughout the whole process

5

temperature humidity


Verification requirements


Test status

Temperature test (no load)

Alternating damp heat test (no load)

Temperature and humidity range

-55℃~80

20%RH98%RH

20℃~85℃)

Temperature deviation

±2

±2

Humidity deviation

/

+2-3%RH(75%RH)

±5%RH(75% RH)

Evenness

temperature

2

2

humidity

/

3%RH(75%RH)

5%RH(75% RH)

Volatility

temperature

±0.5

±1

humidity

/

±3%RH

6

Circulating wind in the box

The average wind speed complies with the requirements of GB/T 10592-2008 and can be automatically adjusted with each test item in the no-load, test-piece unloaded, and test-piece loaded state.

7

Electrical insulation

The electrical insulation performance of the equipment meets the relevant national standards

8

noise

The compressor cabinet has a silent design, and the noise of the whole machine is ≤63dB (the measurement method is carried out according to the requirements of Article 8.5 of GB/T 5170.2-2008). If there is a soundproof room, it is the noise outside the room.

9

Vibration and shock

All equipment and its components should be able to withstand shock and vibration during use without damage or failure;


All equipment and its components should be able to withstand shock and vibration during transportation and installation without damage or failure.



Features

The European intelligent expansion valve system + the American pulse refrigeration battery valve control system automatically adjusts the refrigerant flow according to the load, saves water and electricity, and adopts the latest research and development of cold-end balancing technology, that is, the equipment controller will be based on the current test conditions of the equipment. Automatic calculation and control of the energy output of the equipment's refrigeration system. Compared with the traditional cooling capacity, the heat balance method of constant temperature and humidity through thermal hedge is more energy-saving, water-saving and energy-saving. (The energy consumption value of the equipment is only 30% of the traditional equipment under high temperature and humidity conditions)

0512-83555991