Fixed spectrum, full spectrum, temperature, humidity test, meet various standards
Support hotline:0512-83555991
Xenon lamp aging test box adopts high stability platinum temperature resistance body, color LCD touch screen temperature controller, 100 groups of 999-segment programming, 999 cycle settings can be alternated, and multiple groups of PID control functions are provided to meet the temperature test standards The air circulation system can simulate different temperature changes and different environments such as high temperature and low temperature, low temperature and high temperature, constant temperature and humidity, and is equipped with a high-accuracy programming system that is easy to operate and learn to provide the best test performance conditions
ADICO xenon lamp aging test chamber meets the standards:
GB/T16422.2 2014 Plastic Laboratory Light Source Exposure Test Method (Part 2: Arc Xenon Lamp)
GB/T2423.24 2013 Environmental Test of Electronic and Electrical Products Part 2: Simulating Solar Radiation on the Ground
GB/T16422.2 2014 Plastic Laboratory Light Source Exposure Test Method (Part 2: Arc Xenon Lamp)
GB/T2423.24 2013 Environmental Test of Electronic and Electrical Products Part 2: Simulating Solar Radiation on the Ground
Test excerpts and must meet the standard catalogue 10.2.5.5 Weathering test (climate simulation test) The instrument should be placed on the base, and the operating orientation in the weathering device is usually exposed to the side facing the weather, the light source of the test chamber and the water spray. The weathering cycle is 14 days in total, and each 2-hour cycle should include 102 minutes of exposure and 18 minutes of light and water spray. The light source should be a xenon arc lamp filter that uses the inner and outer optics of borosilicate glass to simulate the spectral power distribution of natural daylight. The measured irradiance should be kept at 0.35 W/m2 at 340 nm during the entire test. In the light only part of the cycle, the temperature of the black panel should be kept at 63 ℃. After the test, the wiring terminals of the meter must be easy to disassemble, there must be no signs of corrosion or discoloration or contamination of the finished material, and the operation must be correct. After the test, the meter must work normally and observe the accuracy of high load, low load and inductive load.
Standard catalog:
GB/T16422.2 2014 Plastic Laboratory Light Source Exposure Test Method Part 2: Xenon Arc Lamp (weathering test)
ISO 4892 2 2013 Plastics. Methods of exposure to laboratory light sources.Part 2: Xenon arc lamps
GB/T 2423.24 2013 Environmental Test Part 2 Test Method Test Sa Simulating Solar Radiation on the Ground and Its Test Guidelines
IEC 60028 2 5 2018 Environme ntal testing. Part 2 5: Tests. Test S: Simulated solar radiation at ground level and guidance for solar radiation testing and weathering
Volume, size and weight | |
Nominal internal volume is about | 0.512m3 can be customized |
Inner box size | 800×800×800 (D×W×H, unit mm) |
Approximate size | 1500×1400×1800 (D×W×H, unit mm) |
Covers an area less than | 2300×2200mm (depth×width) |
weight | About 1000kg |
Performance | |
Test environment conditions | Ambient temperature is +25℃, relative humidity is ≤85% |
Temperature in the box | 20℃~85℃, the interval can be adjusted and can be set |
Blackboard temperature range | 40℃~120℃ |
Humidity range | 20%—98% 相对湿度;监控的分辨率为0.1%RH |
Humidity uniformity | ±3%R.H (>75%R.H) ±5%R.H (≤75%R.H) |
Temperature fluctuation | ≤±0.5℃ |
Temperature uniformity | ≤±2.0℃ |
Temperature deviation | ≤±2.0℃ |
Humidity deviation | ≤±3%RH |
Lamp wavelength | 300~800nm full spectrum light source 6.5KW*1 Transparent filter can transmit 300~400nm ultraviolet light
|